TYF-30智能粉塵采樣器直銷是我公司推出的粉塵采樣器。該儀器選用美國單片機作智能控制中央處理器,使儀器更具適用性。流量(可選):5~30L/min、3~30L/min、5~25L/min微電腦恒流(liu)系統控制、LCD數顯系統、菜單設定、交直流(liu)兩用,選(xuan)配(pei)鋰電池(chi)供(gong)電
一、TYF-30智能粉塵采樣器直銷技術參(can)數及工(gong)作條件:
采樣流(liu)量范圍:5~30L/min
流量誤差:≤±5%
定(ding)時(shi)誤差(cha):≤±1%o
zui大(da)負壓(ya):≥25000Pa
充(chong)電電流:300nA(標準(zhun)型)
電 源:10VDC、220V50HAC
工作溫度(du):-10-40℃
噪 聲:≤60dB
相對濕度:≤85%
體 積:200x160x140mm
二、TYF-30智能粉塵采樣器直銷使(shi)用與維護:
1、采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang) 裝好帶(dai)濾膜夾的采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)頭,按(an)(an)(an)壓“開(kai)(kai)關”鍵二秒,進(jin)(jin)入開(kai)(kai)機(ji)畫(hua)面,按(an)(an)(an)“取(qu)消”鍵進(jin)(jin)入“功(gong)能(neng)設置(zhi)”,用上下鍵進(jin)(jin)入“采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)方(fang)式設置(zhi)”或“系(xi)統功(gong)能(neng)設置(zhi)”,如選擇(ze)采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)方(fang)式設置(zhi),按(an)(an)(an)“確認(ren)”再按(an)(an)(an)“左”、“右”鍵選擇(ze)連續(xu)采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)或間(jian)(jian)歇采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)(一般多為(wei)連續(xu)采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)),按(an)(an)(an)“上”、“下”鍵選擇(ze)采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)時(shi)間(jian)(jian)和停止時(shi)間(jian)(jian)(在間(jian)(jian)歇采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)模式下)。系(xi)統功(gong)能(neng)設置(zhi)無(wu)操作關機(ji)建議1-3秒,背光燈(deng)時(shi)間(jian)(jian)5秒左右,設置(zhi)完畢按(an)(an)(an)“取(qu)消”鍵進(jin)(jin)入“確認(ren)”采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)時(shi)間(jian)(jian)。菜單設定一次調好后(hou)下次開(kai)(kai)機(ji),只要(yao)按(an)(an)(an)“開(kai)(kai)機(ji)”鍵再選擇(ze)所需時(shi)間(jian)(jian)按(an)(an)(an)“確認(ren)”即可開(kai)(kai)機(ji)采(cai)(cai)(cai)(cai)樣(yang)(yang)(yang)。
2、充電 該儀器顯示屏顯示電池容量,此圖形為滿電,當圖形為 表示欠壓需充電。充電時只需將電池線接上交流市電與采樣器連續即可進行全自動充電。充電完畢主機指示燈由紅色變為綠色。
3、注(zhu)意事項 若3個月以上不(bu)用應進行補(bu)充電,以確保高能鎘(ge)鎳電池的使(shi)用壽命。
在含塵較多的空(kong)氣中,應在開機前裝好,帶濾膜的采樣頭,否(fou)則塵粒進入機內影響氣路的器件清潔。
三、TYF-30儀器附件:
儀器箱(xiang) 1只
采樣頭 1只
采樣夾 2只
三角架 1副
濾(lv)膜(mo) 1盒
電源線 1根
說明書 1份
合(he)格證 1份